EN1I-6197Issue 7 (02/04)DCP301Digital Program ControllerUser’s Manual

Página 2 - TECHNICAL ASSISTANCE

viii Display in program operation mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3 Display in constant-value operation mode . . .

Página 3 - SAFETY PRECAUTIONS

Chapter 7. PARAMETER SETUP7-15● D v -L (3-position control deviation lower limit)● D v -H (3-position control deviation upper limit)● H Y -L (3-positi

Página 4

Chapter 7. PARAMETER SETUP7-16● M .-C (motor control method selection)0: MFB control (conventional) + estimated position control1: MFB control (conven

Página 5

Chapter 7. PARAMETER SETUP7-17● M .-A t (motor valve opening automatic adjustment)0: Adjustment disabled1: Adjustment enabledThis parameter automatica

Página 6 - Unpacking

Chapter 7. PARAMETER SETUP7-18 Event configuration data settings “E v”No. Item Code Item Factory User SettingSetting Setting1 E T 1 02 E D 1 03 H

Página 7

Chapter 7. PARAMETER SETUP7-19No. Item Code Item Factory User SettingSetting Setting5 E T 2 06 E D 2 07 H Y S 2 58 D L 2 0PV type events0: PV direct

Página 8 - Contents

Chapter 7. PARAMETER SETUP7-20No. Item Code Item Factory User SettingSetting Setting9 E T 3 010 E D 3 011 H Y S 3 512 D L 3 0PV type events0: PV dir

Página 9

Chapter 7. PARAMETER SETUP7-21No. Item Code Item Factory User SettingSetting Setting13 T T 0 0: T1 to T5 are all time events.1: T1 is a segment No. ev

Página 10 - Chapter 8. PROGRAM SETUP

Chapter 7. PARAMETER SETUP7-22 Description of event configuration data● E D 1 (event 1 standby)● E D 2 (event 2 standby)● E D 3 (event 3 standby)0:

Página 11 - Chapter 9. TROUBLESHOOTING

Chapter 7. PARAMETER SETUP7-23 PID parameter settings “P I d”No. Item Code Item Factory User SettingSetting Setting1 P -1 100.02 1 -1 03 D -1 04 O L

Página 12 - Chapter 11. CALIBRATION

Chapter 7. PARAMETER SETUP7-24No. Item Code Item Factory User SettingSetting Setting21 P -3 100.022 1 -3 023 D -3 024 O L -3 0.025 O H -3 100.026 R E

Página 13 - RUN/HOLD

8-2 Copying Programs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-14 Operation. . . . . . . . . . . .

Página 14 - 1-1 Features

Chapter 7. PARAMETER SETUP7-25No. Item Code Item Factory User SettingSetting Setting41 P -5 100.042 1 -5 043 D -5 044 O L -5 0.045 O H -5 100.046 R

Página 15 - 1-2 Basic Function Blocks

Chapter 7. PARAMETER SETUP7-26No. Item Code Item Factory User SettingSetting Setting61 P -7 100.062 1 -7 063 D -7 064 O L -7 0.065 O H -7 100.066 R

Página 16 - 1-3 Data Structure

Chapter 7. PARAMETER SETUP7-27 Setup data settings “S E t”No. Item Code Item Factory User SettingSetting Setting1 C 0 1 02 C 0 2 03 C 0 3 04 C 0 4 N

Página 17 - 1-4 System Configuration

Chapter 7. PARAMETER SETUP7-28No. Item Code Item Factory User SettingSetting Setting11 C 1 1 012 C 1 2 013 C 1 3 014 C 1 4 015 C 1 5 016 C 1 6

Página 18 - 1-5 Model Numbers

Chapter 7. PARAMETER SETUP7-29No. Item Code Item Factory User SettingSetting Setting31 C 3 1 –32 C 3 2 –33 C 3 3 –34 C 3 4 –35 C 3 5 –36 C 3 6 –37 C

Página 19 - 2-1 Structure

Chapter 7. PARAMETER SETUP7-30No. Item Code Item Factory User SettingSetting Setting50 C 5 0 051 C 5 1 100052 C 5 2 053 C 5 3 054 C 5 4 055 C 5 5 100

Página 20 - 2-2 Console

Chapter 7. PARAMETER SETUP7-31No. Item Code Item Factory User SettingSetting Setting67 C 6 768 C 6 8 069 C 6 q 070 C 7 0 071 C 7 1 072 C 7 2 073 C 7

Página 21

Chapter 7. PARAMETER SETUP7-32No. Item Code Item Factory User SettingSetting Setting82 C 8 2 083C 8 3 —84C 8 4 085 C 8 5 086 C 8 6 —87 C 8 7 —88 C 8 8

Página 22 - Basic display state

Chapter 7. PARAMETER SETUP7-33Input (X)Y=(X/100)1/2 x 100Output after square rootextraction (Y)Dropout value(variable in range 0.1 to 10.0%)100%100%MV

Página 23

Chapter 7. PARAMETER SETUP7-34OFFON20% 50% 40%OFFON20% 50% 40%Setting=0Setting=1Cycle time Cycle timeCycle time Cycle timePID operation resultPID oper

Página 24

Items cannot be changed by pressing , in program setup state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 25 - ■ Loader jack

Chapter 7. PARAMETER SETUP7-35● C 7 8 (voltage output 1 adjustment)● C 7 q (voltage output 2 adjustment)When driving an SSR by voltage time-proportion

Página 26 - 2-3 Input Type and Range No

Chapter 7. PARAMETER SETUP7-36(3) Equivalent circuit when N number of SSRs are connected in seriesDCP301 SSR 1IO(VO)VSSR'ZVDSSR N+–VSSR'ZVD–

Página 27

Chapter 7. PARAMETER SETUP7-37(5) Example: Using Yamatake Corporation’s PGMVSSR : 3 to 6VZ : 260Ω ± 5%VD : 0.8 to 1.3V• What value should IO be set to

Página 28 - Chapter 3. MOUNTING

Chapter 7. PARAMETER SETUP7-38(2) Turn the DCP301 ON again, and set setup data C q 0 setting to 241. For details onhow to change settings, see 7-1 Par

Página 29 - 3-2 Panel Cutout Dimensions

Chapter 7. PARAMETER SETUP7-39● C 9 3 (CPL communications port selection)• When set to 0, CPL communications from the loader jack is not possible. In

Página 30 - 3-3 Mounting

Chapter 7. PARAMETER SETUP7-40No. Item Code Item Factory User SettingSetting Setting1 T -A . 1 0U2 T -A . 2 1000U3 T -A . 3 1000U4 T -A . 4 1000U5

Página 31 - ■ Dust-proof cover

Chapter 7. PARAMETER SETUP7-41(A2, B2) (A1, B1) B-axisA-axis1234567981011B-axis (output)Fixed value(10000, 10000)A-axis (input)Fixed value(-2000, -200

Página 32 - ■ Mounting method

Chapter 7. PARAMETER SETUP7-42 Constant-value operation data settings “C N S t”No. Item Code Item Factory User SettingSetting Setting1 M .O D E 02 S

Página 33 - 4-1 Wiring Precautions

Chapter 8. PROGRAM SETUP8-1Chapter 8. PROGRAM SETUP8-1 Program SetupPrograms can be set up when the DCP301 is in the basic display state. This is some

Página 34

Chapter 8. PROGRAM SETUP8-2● Selecting the program No. after entering program setup (continued)When you select the program No. by this method, the dis

Página 35 - 4-2 Compensating Lead

xiConventions Used in This ManualThe following conventions are used in this manual.Handling Precautions:Handling Precautions indicate items that the u

Página 36 - 4-3 Terminal Connections

Chapter 8. PROGRAM SETUP8-3● Description of mode transition states (see page 8-2.)(1) Program setup is entered.(2) Setup item on programming map is mo

Página 37 - Direction

Chapter 8. PROGRAM SETUP8-4 Programming mapAs shown in the figure below, the programming map is arranged in a matrix with thesegment Nos. aligned alo

Página 38 - ■ Ground

Chapter 8. PROGRAM SETUP8-5SPTM– –– –– –– –: LED litProgram/Segment No. DisplayBasic indicator LED lampsProgram No. Segment No.PatterntendencyUpper di

Página 39 - Chapter 4. WIRING

Chapter 8. PROGRAM SETUP8-6 Setting up events 1 to 3 items● When event type is PV type event(1) In the setting display state, move to the event 1 to

Página 40 - ■ Connecting input 1

Chapter 8. PROGRAM SETUP8-7● When event type is time event(1) In the setting display state, move to the event 1 to 3 items of the segment to be set up

Página 41

Chapter 8. PROGRAM SETUP8-8 Setting up time events 1 to 5(1) In the setting display state, move to the event 1 to 5 items of the segment to be set up

Página 42

Chapter 8. PROGRAM SETUP8-9 Setting up PID set No. items(1) In the setting display state, move to the PID set No. items of the segment to be set upon

Página 43

Chapter 8. PROGRAM SETUP8-10 Setting up G.Soak (guarantee soak) items(1) In the setting display state, move to the G.Soak item of the segment to be s

Página 44

Chapter 8. PROGRAM SETUP8-11PV start setting valueProgram No. Segment No.PatterntendencyEV1 to EV3 and T1 to T5 all outP.S T A Setting up PV start it

Página 45

Chapter 8. PROGRAM SETUP8-12Program No. Segment No.PatterntendencyEV1 to EV3 and T1 to T5 all outC L R. Setting up pattern link items(1) In the setti

Página 46

Chapter 1. GENERAL1-1Chapter 1. GENERAL1-1 FeaturesThe DCP301 is a general-purpose single-loop program controller for controlling temperature, pressur

Página 47

Chapter 8. PROGRAM SETUP8-13 Inserting and deleting segments(1) In the setting display state, move to the pattern item of the segment where the seg-m

Página 48 - ■ RS-485 interface

Chapter 8. PROGRAM SETUP8-148-2 Copying ProgramsThe DCP301 can be set for copying programs in the program operation READY mode in the basic display st

Página 49

Chapter 8. PROGRAM SETUP8-158-3 General ResetA general reset can be executed when the DCP301 is in the READY AUTO mode in the basic display state. If

Página 50

Chapter 9. TROUBLESHOOTING9-1Chapter 9. TROUBLESHOOTING9-1 Self-diagnostics and Alarm Code DisplaySelf-diagnostics functions are incorporated into the

Página 51 - Digital circuit

Chapter 9. TROUBLESHOOTING9-2Alarm Code Alarm Name DescriptionA L 0 1 Input 1 over-rangeA L 0 2 Input 1 under-rangeA L 0 7 Input 1 RTD disconnection

Página 52 - 5-1 Data

Chapter 9. TROUBLESHOOTING9-3The controller is in the READY mode.Key lock is enabled.PressRUN/HOLDto set the controller to the RUN mode. (Thecontrolle

Página 53 - 5-2 Program Patterns

Chapter 9. TROUBLESHOOTING9-4PressRUN/HOLDto set the controller to the RUN mode. (Thecontroller can be reset in case of external switch inputor commun

Página 54 - ■ Events 1 to 3

Chapter 9. TROUBLESHOOTING9-5 Auto-tuning (AT) is not canceled by pressingATin the basic display stateKey lock is enabled. Set variable parameter L O

Página 55 - Chapter 5. FUNCTIONS

Chapter 9. TROUBLESHOOTING9-6 PID set items cannot be displayed by repeatedly pressing in program setupstate Items cannot be changed by pressing in

Página 56

Chapter 9. TROUBLESHOOTING9-7 Insertion/deletion of segments cannot be confirmed by pressingFUNC+ENTin pro-gram setup stateThe program setup cannot b

Página 57 - ■ Time events 1 to 5

Chapter 1. GENERAL1-24 external switch inputs• RUN• HOLD• RESET• ADV* indicates options.Input• Thermocouple• Resistance • dc current• dc voltage8 ex

Página 58

Chapter 9. TROUBLESHOOTING9-89-3 Motor Adjustment is ImpossibleThere are two ways of wiring a motor to the DCP301: wiring for direct motor rotation an

Página 59 - ■ PID set selection

Chapter 9. TROUBLESHOOTING9-9Upper Display Lit LEDs Lower Display Motor Action RemarksC A .C L OT2 CCW↓C A .O P OT1 CWUpper Display Lit LEDs Lower Dis

Página 60 - (1)"

Chapter 9. TROUBLESHOOTING9-10CAUTIONBefore replacing the battery, be sure to turn the power OFF. Failure to doso might cause electric shock.Do not to

Página 61 - ■ Pattern link

Chapter 9. TROUBLESHOOTING9-11 Replacement procedure• Replace with the lithium battery set (model No.: 81446431-001). The lithiumbattery set can be o

Página 62 - 5-3 Modes

Chapter 9. TROUBLESHOOTING9-12 Connector(6) Place the body on its save on a desk or flat surface so that the side on which thebattery is installed is

Página 63

Chapter 9. TROUBLESHOOTING9-13(12) Fit the battery into the gray holder so that the battery cable is above the RAM board.Gray holder(13) Insert the bo

Página 64 - ■ Mode transition

Chapter 10. SPECIFICATIONS10-11930 per programRAMP-X system: Set by set points (SP) and time.0 to 99h 59min, or 0 to 99min 59s (time unit selectable)±

Página 65 - ■ Mode transition operations

Chapter 10. SPECIFICATIONS10-2Over-range detectionthresholdCold junction compensa-tion accuracyInfluence of surroundingtemperature on coldjunction com

Página 66 - ■ Mode transition limitations

Chapter 10. SPECIFICATIONS10-3READY: Ready to run program (control stop/program No. selectable)RUN: Program runHOLD: Program holdFAST: Program fast-fo

Página 67 - 5-4 Controller and Programmer

Chapter 10. SPECIFICATIONS10-4PV, SP, deviation, MV, MFBSupported1/10000Contact type: 1a1bContact rating: 5A (30Vdc, resistive load)5A (120Vac, resist

Página 68

Chapter 1. GENERAL1-31-3 Data StructureData is made up of “parameters” that are used mainly for setting controller functions and “programs” that are u

Página 69 - ■ Control output

Chapter 10. SPECIFICATIONS10-5Item SpecificationEvent/TimeEventOutputCommu-nicationsEvents 1, 2Event 3Time events 1 to 5Event 1 to 3 settingsTime even

Página 70

Chapter 10. SPECIFICATIONS10-6Item SpecificationGeneralSpecifica-tionsDisplay charactersIsolationMemory backupRated power voltagePower consumptionPowe

Página 71 - ● 2G output

Chapter 10. SPECIFICATIONS10-7Item SpecificationGeneralSpecifica-tionsTransport/storageconditionsFuseTerminal screwTerminal screws tighteningtorqueMas

Página 72 - MANUAL mode

Chapter 10. SPECIFICATIONS10-8(106x104)(18)15159.5137ABABUnit: mm9696B-B3778.4110.5A-A 90.2 91.510-2 External Dimensions

Página 73 - ■ Auxiliary output

Chapter 10. SPECIFICATIONS10-9 Hard dust-proof cover set (sold separately)(transparent polycarbonate)Model No.: 81446083-001816461.1(96.8)1064.796.61

Página 74 - 6-1 Turning the Power ON

Chapter 11. CALIBRATIONThis chapter covers the field calibrations procedures for the inputs, outputs and various functions of the DCP301 andDCP302 con

Página 75 - Chapter 6. OPERATION

Chapter 11. CALIBRATION11-1 Quick Reference Table for Calibration ItemsDCP301 and DCP302 controllers are numbered using the following format. Forma

Página 76

Chapter 11. CALIBRATIONTable 11-2. Item and Sub Item Table for Calibration0.0.0.0. etc.1.0.1.1.2.0.2.2.4.0.4.4.AdJSAdJSUpper Display ShowsLower Disp

Página 77

Chapter 11. CALIBRATIONFigure 11-1. Calibration Flowchart (1/2)11-4Notes: *; 1. This display shows the digits shown in the previous indication.2. If

Página 78

Chapter 11. CALIBRATIONFigure 11-1. Calibration Flowchart (2/2)11-5OUT CH1 20mA count&ENTER&C/J sensor calibration itemPROG SEG0 2 0 1CJ zer

Página 79 - Output state of events 1 to 3

Chapter 1. GENERAL1-41-4 System Configuration System configuration by CPL communicationsOn DCP301 models supporting RS-485 communications (optional),

Página 80 - 6-3 Program Selection

11-2 Calibration Procedures Enter calibration mode(1) Release keylock. (PARALoC=0and PrtC=0)(2) Press DISP key to permit ordinary indication conditi

Página 81

Function testPress ↑, ↓, ←, or → keys to show (0.0.0.0) on upper display, then press ENT key.●Key test (00-01)Press PARA key until the PROG/SEG displ

Página 82 - ■ Program selection

●Display test (00-02)Press PARA key until the display test starts.Then, each 7-segment LED, LED indicators and LCD illuminates at every 0.5 sec.This i

Página 83 - ■ Read timing

●Digital output test for control output (00-04)Press PARA key until the PROG/SEG display shows (00-04).When the digit of upper display is changed by ↑

Página 84 - ■ Auto-tuning (AT)

PV calibrationScroll ↑, ↓, ←, or → keys to show (1.0.1.1.) on upper display, then press ENTkey.●Gain No. selectPress PARA key until the PROG/SEG disp

Página 85

Table 11-11.GroupRange Table of CH1 TCT/CType Code Gain No.K (CA)K (CA)K (CA)K (CA)K (CA)K (CA)E (CRC)J (IC)T (CC)B (PR30-6)R (PR13)S (PR10)W (WRe5-26

Página 86 - 7-1 Parameter Setup

Cold junction sensor calibrationScroll ↑, ↓, ←, or → keys to show (2.0.2.2.) on upper display, then press ENTkey.●The cold junction input 0%(1) Press

Página 87

11-3 Set UpGain No. 0 to 7 Gain No. 16 to 17 Gain No. 9 to 10 Gain No. 19Gain No. 11 to 12(0%) Gain No. 20(0%) Gain No. 11 to 12(100%) Gain No. 20(10

Página 88

Figure 11-11. Current Outputs14 15 17 1811 12+−CH3OUTCH1 CH2OUT OUT+−+−Digital ammeter Copperleads11-14Chapter 11. CALIBRATION

Página 89 - 7-2 How to Use

Program ItemsSegment No.PatternEvent 1Event 2Event 3Timeevent 1Timeevent 2Timeevent 3Timeevent 4Timeevent 5PID set No. (CH1)G.Soak (CH1)G.Soak time-ou

Página 90

Chapter 1. GENERAL1-51-5 Model Numbers Model selection guideP301 Digital Program Controller (single-loop model)0D Relay outputs (on-off, or time-prop

Página 91

1To reduce risk of electric shock which could cause personal injury, all safety notices inthis documentation.This symbol warns the user of a potential

Página 92 - 7-3 Parameter Setup List

IndexIndex-12 degrees of freedom PID selection•••••••••••••7-123-position control deviation lower limit•••••••••7-153-position control deviation upper

Página 93

Index-2Ground••••••••••••••••••••••••••••••••••••••••4-6-H-Hard dust-proof cover set •••••••••••3-1, 10-7, 10-9Heat/cool control dead zone••••••••••••

Página 94

-S-Segment No. display•••••••••••••••••••••••••••2-2Segment deletion •••••••••••••••••••••••••••••8-13Segment insertion•••••••••••••••••••••••••••••8-

Página 95

Revision HistoryPrinted Manual NumberEdition Revised pages DescriptionDate99-04 EN1I-6197 1st Edition00-06 2nd Edition iv Instruction Manual.was chang

Página 96

HONEYWELL SERVICE CENTERSNETHERLANDSHONEYWELL BVLaaderhoogtweg 18NL-1101 EA AMSTERDAM ZOTHE NETHERLANDSTel.:31 20 56 56 911POLANDHONEYWELL LtdUI Augus

Página 97

HONEYWELL SERVICE CENTERSARGENTINAHONEYWELL S.A.I.C.BELGRANO 1156BUENOS AIRESARGENTINATel.:54 1 383 9290AUSTRALIAHONEYWELL LIMITED5 Thomas Holt DriveN

Página 98

No. CP-UM-5093E

Página 99

Chapter 2. NAMES & FUNCTIONS OF PARTS2-1Chapter 2. NAMES & FUNCTIONS OF PARTS2-1 StructureThis controller comprises a body, console, case, sta

Página 100 - Handling Precautions

WARRANTYThe Honeywell device described herein has been manufactured andtested for corrent operation and is warranted for a period of one year.TECHNICA

Página 101

Chapter 2. NAMES & FUNCTIONS OF PARTS2-22-2 ConsoleThe console comprises keys for operating the controller, displays and LEDs. Basic display stat

Página 102

Chapter 2. NAMES & FUNCTIONS OF PARTS2-3• Mode indicator LEDsRUN, HLD: Display the READY, RUN, HOLD, FAST and END modes. (See follow-ing table.)RE

Página 103 - D L 1 0

Chapter 2. NAMES & FUNCTIONS OF PARTS2-4FUNC+DISPPROGPROGPROGA/MAT: Program key: Function key Loader jack: Auto/Manual key: Auto-tuning key: Param

Página 104

Chapter 2. NAMES & FUNCTIONS OF PARTS2-5Starts parameter setup. So the controller enters se-lection of setup group (major item).(in basic display

Página 105

Chapter 2. NAMES & FUNCTIONS OF PARTS2-6Category Function Key operationProgram copyGeneral resetDo not operate the console keys using a sharp-poin

Página 106

Chapter 2. NAMES & FUNCTIONS OF PARTS2-7 Functions using two or more keysPROG+RUN/HOLD: Reset keysPressRUN/HOLDwithPROGheld down in the basic dis

Página 107

Chapter 2. NAMES & FUNCTIONS OF PARTS2-8Input Format Range No. Code Temp. Range (°C) Temp. Range (°F)K (CA) 0 K09 0 to 1200 0 to 2400K (CA) 1 K08

Página 108 - Program or Zone No. According

Chapter 2. NAMES & FUNCTIONS OF PARTS2-9● dc current, dc voltageInput Format Range No. Code Range (programmable)4 to 20mA 64 C010 to 20mA 65 C080

Página 109

Chapter 3. MOUNTING3-1Chapter 3. MOUNTING3-1 External DimensionsB-B3778.4110.5A-A 90.2 91.5Back plateAdd-on terminal baseTerminal screw(106x104)

Página 110

Chapter 3. MOUNTING3-292+0.8 046 4696 x (N - 1)96 x N - 492+0.8 092+0.8 0N=number of units installedPanel cutout dimensionsPanel cut

Página 111

About IconsSafety precautions are for ensuring safe and correct use of this product, and forpreventing injury to the operator and other people or da

Página 112 - ■ Setup data settings “S E t”

Chapter 3. MOUNTING3-3Use the DCP301 within the operating ranges recommended in the specifi-cations (temperature, humidity, voltage, vibration, shock,

Página 113

Chapter 3. MOUNTING3-4 indicates that a function can be used.The varister may become short-circuited when trouble occurs. Pay attention tothis when

Página 114

Chapter 3. MOUNTING3-5Mounting bracket 81405411-001PanelMounting bracket Mounting method• Firmly secure the top and bottom of the controller by the m

Página 115

Chapter 4. WIRING4-1Chapter 4. WIRING4-1 Wiring PrecautionsWire the DCP301 properly according to predetermined standards. Alsowire the DCP301 using de

Página 116

4-2• Before wiring the DCP301, check the controller catalog No. and terminal Nos.on the label on the rear of the body. After wiring the DCP301, be sur

Página 117

Chapter 4. WIRING4-34-2 Compensating LeadIn the case of thermocouple input, connect the bare thermocouple lead to the terminal. If the thermocouple is

Página 118

Chapter 4. WIRING4-44-3 Terminal ConnectionsUse crimped terminals that fit onto M3.5 screws.7.47.3 max.6.6 max.3.7dia.Unit: mm• When installing the DC

Página 119

Chapter 4. WIRING4-54-4 Layout of Terminals and Recommended Lead Draw-outDirectionWiring is carried out on the standard terminal base or add-on termin

Página 120 - SSR'

Chapter 4. WIRING4-64-5 Connecting the Ground and Power Supply Power supplyConnect the DCP301 to a single-phase power supply for controllers, and tak

Página 121

Chapter 4. WIRING4-7* On 2G, 3D or 5K models, (17) and (18) are the auxiliary outputs.On 0D, 5G or 6D models, (14) and (15), and (17) and (18) are th

Página 122 - q 0 (Special functions)

iiWARNINGCAUTIONUse the DCP301 within the operating ranges recommended in the specifica-tions (temperature, humidity, voltage, vibration, shock, mount

Página 123 - Short-circuit

Chapter 4. WIRING4-8313233343132333431323334V, mVCBA31323334mA4-7 Connecting Inputs (analog inputs) Connecting input 1Multiple input 1 supports vario

Página 124

Chapter 4. WIRING4-9WARNING4-8 Connecting control outputs (outputs 1, 2)Before wiring, or removing/mounting the DCP301, be sure to turn the powerOFF.

Página 125 - ■ Table data settings “T B L”

Chapter 4. WIRING4-10111213SSR2 to 22mAdcWith current adjustment function(setup: C78)Voltage output is reliant on an internal fixed-current circuit.Se

Página 126

Chapter 4. WIRING4-11Before wiring, or removing/mounting the DCP301, be sure to turn the powerOFF. Failure to do so might cause electric shock.4-9 Con

Página 127 - MV upper limit (CH1)

Chapter 4. WIRING4-124-10 Connecting Event Output (relay output)Event outputs EV1 and EV2 are 1a contact, and event output EV3 is 1a1b. Event outputs

Página 128

Chapter 4. WIRING4-134-11 Connecting Time Event Output (open-collector)Optional time event outputs T1 to T5 (open-collector outputs) can be added on.

Página 129 - C L R .” blinking

Chapter 4. WIRING4-144-12 Connecting External Switch (RSW) InputThe DCP301 is provided with four external switch inputs as standard (eight optional).

Página 130

Chapter 4. WIRING4-15● Internal circuit for controller components for connecting external switch inputs24212512Vdc12Vdc484112Vdc12VdcStandard terminal

Página 131 - ■ Programming map

Chapter 4. WIRING4-164-13 Connecting for CommunicationsSome controller models support the RS-485 communications interface. Select the RS-485 communica

Página 132 - ■ Display details

Chapter 4. WIRING4-17● 5-wire system RS-485 mutual connection5758596061SDASDBRDARDBSGFG5758596061SDASDBRDARDBRDARDBSDASDBSGFGSGFG5758596061SDASDBRDARD

Página 133 - Program No. Segment No

iiiCAUTIONUse induced lighting surge preventive device if there is the risk of powersurges caused by lightning.Failure to do might cause fire or fault

Página 134

Chapter 4. WIRING4-18● 3-wire system RS-485 mutual connectionProvide terminating resistor of 150Ω±5%, 1/2W min. at both ends of the communications pat

Página 135

Chapter 4. WIRING4-194-14 Isolating Inputs and OutputsThe following figures show isolation between inputs and outputs. Solid lines show isolated items

Página 136

Chapter 5. FUNCTIONS5-1Chapter 5. FUNCTIONS5-1 Data Data typesThe DCP301 supports the following data types.For further details, see Chapter 7, Parame

Página 137

Chapter 5. FUNCTIONS5-25-2 Program Patterns PatternsSP and time comprise the settings for a single segment in a pattern. Up to 30 segmentscan be link

Página 138 - ■ Setting up cycle items

Chapter 5. FUNCTIONS5-3 Events 1 to 3Events 1 to 3 are event configuration data. These are used after setting the event type,event standby, hysteresi

Página 139 - P.L I N

Chapter 5. FUNCTIONS5-4HEVPVHEVPVPV reverseHSP+EVPVDeviation reverseHEVSPSP reverseHEVMVMV reverseHEVMFBMFB reverseHSP+EVPVDeviation directH HEVEVSPPV

Página 140

Chapter 5. FUNCTIONS5-5● Controller status eventsController status events are turned ON and OFF according to the controller mode, alarmstatus and othe

Página 141 - Copy destination program No

Chapter 5. FUNCTIONS5-6 Time events 1 to 5Either of time events or segment No. events can be selected by the time event type itemin the event configu

Página 142 - G .R E S

Chapter 5. FUNCTIONS5-7Segment 8ON timeOFF timeOutput ONOutput OFFG.Soak standbySegment 9ON timeOFF timeOutput ONOutput OFFON=segment timeSegment 10Se

Página 143

Chapter 5. FUNCTIONS5-812 43PID set No.PID set segment designationZone 8Zone 7Zone 6Zone 5Zone 4Zone 3Zone 2Zone 1All SP rangesare divided toeight zon

Página 144 - ■ Alarm categories

EN1I-XXXXIssueX(XX/XX)XXXXXXXXXXXXXXXXXXXXXXXXXXXXXUsers ManualUnpackingivCheck the following when removing the DCP301 from its package.1. Check the

Página 145

Chapter 5. FUNCTIONS5-9ACA'BSP patternStart pointCurrentPV valueStart pointStart point(1)(1)'(1)" PV startIf PV start is set in the pr

Página 146

Chapter 5. FUNCTIONS5-10SPSPSPProgram No.2 pattern-linked to program No.1Program No.1Program No.2TimeTimeTimeProgram No.1 Program No.2 Pattern link“p

Página 147

Chapter 5. FUNCTIONS5-115-3 Modes Mode typesThe following modes are available on the DCP301.READYAUTOMANUALAUTOMANUALAUTOMANUALAUTOMANUALAUTOMANUALAU

Página 148

Chapter 5. FUNCTIONS5-12● RUNIn this mode, the program is running.MV outputs are active in PID control or ON-OFF control, and events and time events a

Página 149

Chapter 5. FUNCTIONS5-13READY AUTOREADY MANUALRUN AUTORUN MANUALRUNRESET Mode transition● During program operationThe solid lines in the following di

Página 150

Chapter 5. FUNCTIONS5-14 Mode transition operationsThe following describes mode transition operations.Though “program end” is not an operation, it is

Página 151

Chapter 5. FUNCTIONS5-15 Mode transition limitationsMode transition can be carried out operating the console keys, external switching inputand commun

Página 152 - 9-4 Replacing the Battery

Chapter 5. FUNCTIONS5-165-4 Controller and ProgrammerOn 5G output models (output catalog No. appended with 5G), you can choose between use as a contro

Página 153 - Lock screw

Chapter 5. FUNCTIONS5-175-5 Input Processing FunctionsInput processing is carried out in the order shown below.(resistance temperature detector)(therm

Página 154 - (approx. 3cm x 8cm)

Chapter 5. FUNCTIONS5-185-6 Output Processing FunctionsThree outputs are provided as output processing functions: control output, SP output and auxili

Página 155 - Gray holder

Organization of This User’s ManualvThis manual is organized as follows.Chapter 1. GENERALThis chapter describes DCP301 applications, features and basi

Página 156 - 10-1 Specifications

Chapter 5. FUNCTIONS5-19● 0D, 6D outputAT executionOver-rangeMANUAL modePID control operationInitialization of PID control operationOutput change limi

Página 157 - Item Specification

Chapter 5. FUNCTIONS5-20● 2G outputOver-rangeREADY modeMFB automatic adjustment executionPID control operationInitialization of PID control operationO

Página 158

Chapter 5. FUNCTIONS5-21READY modeMANUAL modeREADY/AUTO modes READY/AUTO modesTime-proportional relay outputCurrent output 4 to 20mA (0 to 20mA)Time-p

Página 159

Chapter 5. FUNCTIONS5-22 SP outputWhen the DCP301 is selected for use as a programmer, control output is operational. On5G output models, SP output i

Página 160

Chapter 6. OPERATION6-1Chapter 6. OPERATION6-1 Turning the Power ONThe DCP301 is not equipped with a power switch or protective fuses. If necessary, p

Página 161

Chapter 6. OPERATION6-26-2 Switching the Basic DisplayThe “basic display state” of the controller collectively refers to the display state of the prog

Página 162 - ■ Accessories/option list

Chapter 6. OPERATION6-3 Display in program operation mode●DISPfunctionsOutput Model No. Display0D, 5G, 6D Display 1 → Display 2 → Display 5 → Display

Página 163 - 10-2 External Dimensions

Chapter 6. OPERATION6-4● Display 4OUTHeat-side output (%)Cool-side output (%)Program No. Segment No.PatterntendencyOutput states of events 1 to 3, tim

Página 164

Chapter 6. OPERATION6-5● Display 7SPTMSPTimeProgram No. Segment No.PatterntendencyOutput states of events 1 to 3, time events 1 to 5The digit to which

Página 165

Chapter 6. OPERATION6-6● Display 3This display is exclusive to 2G output models (output catalog No. appended with 2G).● Display 4OUTHeat-side output (

Página 166 - Chapter 11. CALIBRATION

ContentsviSafety PrecautionsUnpackingRequestOrganization of the Product ManualConventions Used in This ManualChapter 1. GENERAL1-1 Features. . . . . .

Página 167

Chapter 6. OPERATION6-76-3 Program SelectionThe program No. can be selected on the console within the range 1 to 19. How to select the program No.Pro

Página 168

Chapter 6. OPERATION6-86-4 External Switch (RSW) Operations External switch (RSW) inputsIn all, the DCP301 is provided with 12 external switch inputs

Página 169 - 2.0.2.2

Chapter 6. OPERATION6-9 Program selectionThe program can be selected in the program operation READY mode. The table belowshows program selection by e

Página 170 - 11-2 Calibration Procedures

Chapter 6. OPERATION6-10 Read timing● Timing of RSW1 to 7Inputs RSW1 to RSW7 are read according to the following timing.(1) When input changes state

Página 171 - ■Function test

Chapter 6. OPERATION6-116-5 Manual Operation and Auto-tuning Manual operationIn the MANUAL mode, controller outputs can be manipulated by or on the c

Página 172

Chapter 6. OPERATION6-12• Auto-tuning will not function properly unless the control target is connected.• The time from start to end of auto-tuning va

Página 173

Chapter 7. PARAMETER SETUP7-1Chapter 7. PARAMETER SETUP7-1 Parameter SetupParameters can be set up when the DCP301 is in the basic display state.If th

Página 174 - 1.0.1.1

Chapter 7. PARAMETER SETUP7-2 Moving individual items in the parameter setupWith individual items, item codes are displayed in the upper display and

Página 175 - Table 11-11

Chapter 7. PARAMETER SETUP7-3• Example of individual item matrix (setup date)Setting group selection(major items)Individual items(minor items)Setting

Página 176 - ■Current output calibration

Chapter 7. PARAMETER SETUP7-47-2 How to Use PARAUsePARAfor calling up individual items in frequently changed parameters. How to register functions to

Página 177 - 11-3 Set Up

vii4-7 Connecting Inputs (analog inputs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8 Connecting input 1. . . . . . . . . .

Página 178

Chapter 7. PARAMETER SETUP7-5● ExampleLet’s register four individual items toPARA. If you pressPARAin the basic display state,the 1st to 4th individua

Página 179 - Programming Map

Chapter 7. PARAMETER SETUP7-6Basic Display StateMax. 8 itemsENTkeyENTkeyENTkeyENTkeyENTkeyENTkeyENTkeyENTkeyPARAkeyPARAkeyPARAkeyPARAkeyPARAkeyPARAkey

Página 180 - SAFETY REQUIREMENTS

Chapter 7. PARAMETER SETUP7-7No. Item Code Item Factory User SettingSetting Setting1 L O C02 P R T C03 F L0.04 P B 10U5 S B 1 0U6 O T L0.07 1 O U T 0

Página 181

Chapter 7. PARAMETER SETUP7-8No. Item Code Item Factory User SettingSetting Setting12 G 5 .T 2.013 C P . 1 1 0U14 C P . 1 2 200U15C P . 1 3 400U16C P

Página 182

Chapter 7. PARAMETER SETUP7-9No. Item Code Item Factory User SettingSetting Setting29 M .-C 030 M .-A T 031 M .-C L 100032 M .-O P 900033 M .-T 30.00:

Página 183

Chapter 7. PARAMETER SETUP7-10 Description of variable parameter settings● L O C (key lock)0: Key lock disabled1: Display of setup data settings disa

Página 184 - Revision History

Chapter 7. PARAMETER SETUP7-11● O T L (MV change limit)The MV is increased or decreased by the same value so that the output change is taken asthe lim

Página 185 - HONEYWELL SERVICE CENTERS

Chapter 7. PARAMETER SETUP7-12● S t (smart-tuning method selection)0: Smart-tuning is disabled.1: The brake value is fixed to inhibit overshoot.2: Ove

Página 186

Chapter 7. PARAMETER SETUP7-13● D I F F• ON-OFF control differentialWhen P is set to 0.0 on both 0D and 6D output models, control is set to ON-OFF co

Página 187 - No. CP-UM-5093E

Chapter 7. PARAMETER SETUP7-14DeadzoneOutput(heat)Output(cool)MV100%50%0%100%Control outputvaluesDead zone<0DeadzoneOutput(heat)Output(cool)MV100%5